A distributor in Southeast Asia bought sixty backstops over two years from three suppliers. All arrived with a one-line inspection certificate: "rated torque tested, passed". Failures occurred in roughly one unit in twelve, always within the first six months, always with the same two signatures — uneven sprag contact marking and race pitting. The rated torque test had been passed by every one of them, because a short static reverse-hold at rated torque proves almost nothing about a backstop.
Rated torque is one property out of about ten that determine whether a backstop survives. A factory acceptance test (FAT) that verifies only torque transfers all the remaining risk to the buyer. This article sets out what a meaningful FAT looks like and what records should travel with the shipment.
A static reverse-hold at rated torque confirms only that the sprags can wedge and that the housing does not burst. It says nothing about:
The table below is a practical acceptance programme for a 6 kN·m class sprag backstop. It is written so that each item produces a number that can be compared with a specification, and a record that can be filed and audited.
| Item | Test method | Acceptance criterion | Record |
|---|---|---|---|
| 1. Reverse locking torque | Lock at 100% and 125% of rated, hold 60 s, measure slip | No measurable slip at 100%, ≤ 0.05° creep at 125% | Torque-time trace, signed |
| 2. Torque-versus-angle curve | Encoder 0.01°, load in 25% steps, 10 repeats | Angle within specification at operating temperature; repeatability ≤ 0.1° | Curve plot per serial number |
| 3. Drag torque | No-load drive at maximum freewheeling speed | Below the value used in the thermal calculation | Torque and speed values |
| 4. Lift-off speed (sprag types) | Speed sweep with drag measurement | Lift-off speed below maximum running speed, engagement response still acceptable | Drag-speed plot |
| 5. Temperature rise | 30 min freewheeling at max speed, thermocouples on housing and seal | Housing ≤ rated continuous temperature; seal below elastomer limit | Temperature log |
| 6. Dimensional | Bore, width, runout, flange squareness, keyway, mounting face | Per drawing, with fit class stated | Dimensional report with actual values |
| 7. Contact pattern | Blue-check on a sample unit from the batch | ≥ 80% of sprags with even marking across the band | Photograph with serial reference |
| 8. Material verification | Hardness traverse (surface and core), case depth, chemistry certificate | Race 59–62 HRC, sprags per spec, case depth per drawing | Metallurgical report with heat numbers |
| 9. Surface integrity | Ra of contact bands, nital etch for grinding burn | Ra ≤ 0.2 µm, no burn | Surface report |
| 10. Dynamic cycling | 5,000–10,000 lock/unlock cycles at rated torque (type test) | Torque retention ≥ 95%, no torque increase in drag, contact pattern unchanged | Type-test report |
| 11. Traceability | Serial number linked to heat numbers, test records, inspector | Complete chain from melt to shipment | Traceability dossier |
Sampling logic: items 1, 2, 3, 6 and 11 on every unit; items 5, 7, 8 and 9 per batch (define the batch, for example 50 units or one heat); items 4 and 10 as type tests per series, repeated when design or supplier changes. This structure keeps the cost per unit reasonable while leaving no unverified assumption in the reliability case.
| Series | FAT emphasis |
|---|---|
| BS | Torque, dimensional and contact pattern; drag and lift-off where freewheeling speed is significant |
| BSEU | Add seal integrity and ingress protection verification; grease quantity confirmed by weight |
| RSBW | Add drag torque and thermal test at gearbox oil flow, plus lift-off speed and torque-angle curve |
| FRHD | Add reaction force verification at the torque arm or mounting interface, plus full-torque static hold and dimensional check on the large bore |
Red flags in a supplier's answer: "we test every unit at rated torque, that is enough"; refusal to state the shock basis of the rating; a hardness value quoted as a range wider than 5 HRC; no serial-to-heat traceability; a type-test report with no date or specimen identification; and any offer to send the record "after shipment".
Q: Is a FAT at rated torque sufficient for a critical conveyor?
A: No. It verifies strength, not reliability. Add torque-angle, drag, contact pattern and material verification to cover the actual failure modes.
Q: What is the single most valuable extra test?
A: The contact pattern blue-check. It exposes alignment, sprag seating and manufacturing quality in one photograph, and it is cheap.
Q: Should every unit be dynamically cycled?
A: Normally no — dynamic cycling is a type test. But require it whenever the series, design or manufacturing source changes, and hold the report.
Q: How do I handle a supplier who cannot provide hardness data?
A: Treat the material claim as unverified. In backstop duty, unverified hardness is the most expensive saving available to a manufacturer and the most costly risk to the buyer.
A distributor in Southeast Asia bought sixty backstops over two years from three suppliers. All arrived with a one-line inspection certificate: "rated torque tested, passed". Failures occurred in roughly one unit in twelve, always within the first six months, always with the same two signatures — uneven sprag contact marking and race pitting. The rated torque test had been passed by every one of them, because a short static reverse-hold at rated torque proves almost nothing about a backstop.
Rated torque is one property out of about ten that determine whether a backstop survives. A factory acceptance test (FAT) that verifies only torque transfers all the remaining risk to the buyer. This article sets out what a meaningful FAT looks like and what records should travel with the shipment.
A static reverse-hold at rated torque confirms only that the sprags can wedge and that the housing does not burst. It says nothing about:
The table below is a practical acceptance programme for a 6 kN·m class sprag backstop. It is written so that each item produces a number that can be compared with a specification, and a record that can be filed and audited.
| Item | Test method | Acceptance criterion | Record |
|---|---|---|---|
| 1. Reverse locking torque | Lock at 100% and 125% of rated, hold 60 s, measure slip | No measurable slip at 100%, ≤ 0.05° creep at 125% | Torque-time trace, signed |
| 2. Torque-versus-angle curve | Encoder 0.01°, load in 25% steps, 10 repeats | Angle within specification at operating temperature; repeatability ≤ 0.1° | Curve plot per serial number |
| 3. Drag torque | No-load drive at maximum freewheeling speed | Below the value used in the thermal calculation | Torque and speed values |
| 4. Lift-off speed (sprag types) | Speed sweep with drag measurement | Lift-off speed below maximum running speed, engagement response still acceptable | Drag-speed plot |
| 5. Temperature rise | 30 min freewheeling at max speed, thermocouples on housing and seal | Housing ≤ rated continuous temperature; seal below elastomer limit | Temperature log |
| 6. Dimensional | Bore, width, runout, flange squareness, keyway, mounting face | Per drawing, with fit class stated | Dimensional report with actual values |
| 7. Contact pattern | Blue-check on a sample unit from the batch | ≥ 80% of sprags with even marking across the band | Photograph with serial reference |
| 8. Material verification | Hardness traverse (surface and core), case depth, chemistry certificate | Race 59–62 HRC, sprags per spec, case depth per drawing | Metallurgical report with heat numbers |
| 9. Surface integrity | Ra of contact bands, nital etch for grinding burn | Ra ≤ 0.2 µm, no burn | Surface report |
| 10. Dynamic cycling | 5,000–10,000 lock/unlock cycles at rated torque (type test) | Torque retention ≥ 95%, no torque increase in drag, contact pattern unchanged | Type-test report |
| 11. Traceability | Serial number linked to heat numbers, test records, inspector | Complete chain from melt to shipment | Traceability dossier |
Sampling logic: items 1, 2, 3, 6 and 11 on every unit; items 5, 7, 8 and 9 per batch (define the batch, for example 50 units or one heat); items 4 and 10 as type tests per series, repeated when design or supplier changes. This structure keeps the cost per unit reasonable while leaving no unverified assumption in the reliability case.
| Series | FAT emphasis |
|---|---|
| BS | Torque, dimensional and contact pattern; drag and lift-off where freewheeling speed is significant |
| BSEU | Add seal integrity and ingress protection verification; grease quantity confirmed by weight |
| RSBW | Add drag torque and thermal test at gearbox oil flow, plus lift-off speed and torque-angle curve |
| FRHD | Add reaction force verification at the torque arm or mounting interface, plus full-torque static hold and dimensional check on the large bore |
Red flags in a supplier's answer: "we test every unit at rated torque, that is enough"; refusal to state the shock basis of the rating; a hardness value quoted as a range wider than 5 HRC; no serial-to-heat traceability; a type-test report with no date or specimen identification; and any offer to send the record "after shipment".
Q: Is a FAT at rated torque sufficient for a critical conveyor?
A: No. It verifies strength, not reliability. Add torque-angle, drag, contact pattern and material verification to cover the actual failure modes.
Q: What is the single most valuable extra test?
A: The contact pattern blue-check. It exposes alignment, sprag seating and manufacturing quality in one photograph, and it is cheap.
Q: Should every unit be dynamically cycled?
A: Normally no — dynamic cycling is a type test. But require it whenever the series, design or manufacturing source changes, and hold the report.
Q: How do I handle a supplier who cannot provide hardness data?
A: Treat the material claim as unverified. In backstop duty, unverified hardness is the most expensive saving available to a manufacturer and the most costly risk to the buyer.